One of the main issues will be the exit through the roof for the flue itself. As conservatories tend to be UPVC, the worry is that the surroundings will melt over time.The solution is to adhere to distance to combustibles, as well as ingenuity in converting a panel to an A1 fire-rated material, which is a non-combustible material BS EN 13501-1.
For an existing conservatory, the advice is to remove the panel section where the chimney will pass through and then replace it with an A1 fire-rated material. The panel itself will need to be weatherproofed and sealed with A1 fire rated sealant.
A typical example of an installation was from
A S Chimneys, and it showed that working in conjunction with the customer and conservatory supplier meant that the correct installation method was used, adhering to safety standards.
The customer required the stove in the corner at 45 degrees, but a structural beam over the top of the stove prevented a straight system internally. The decision was made to supply an aluminium blank in place of the roof panel, which enabled A S Chimneys to seal lead flashing and keep insulation at a suitable distance from the flue. A S Chimneys regularly use this method for all conservatory installs.